{"product_id":"tsl-mci-gen2","title":"Tesla, Mid-Circuit Interrupter High Current (MCI-2), 1879359-15-B","description":"\u003ch2\u003eTesla, Mid-Circuit Interrupter High Current (MCI-2), 1879359-15-B\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan data-subtree=\"aimfl,mfl\" data-processed=\"true\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cspan data-sfc-root=\"c\" data-wiz-uids=\"WhJT8_h\" data-sfc-cb=\"\" data-processed=\"true\"\u003eTesla Mid-Circuit Interrupter (MCI-2) High Current\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(1879359-15-B)\u003c\/strong\u003e\u003cspan\u003e is \u003c\/span\u003ea Second Generation (Gen 2) PV Rapid Shutdown (RSD) device designed for high-current solar modules.\u003cspan\u003e It ensures safety compliance by enabling quick, module-level de-energization for Tesla Powerwall 3, Powerwall+, and Tesla Solar Inverters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Product Details:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eVariant:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh Current MCI-2 (19A).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1879359-15-B.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eMax Input Current\u003cspan\u003e (\u003cem\u003eISC\u003c\/em\u003e): \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e19 A.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eNominal Input Current\u003cspan\u003e (\u003cem\u003eIMP\u003c\/em\u003e): \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"Yjhzub\"\u003e15 A.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eMax System Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1000 V DC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 Watts.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for high-current PV modules in tandem with Tesla Inverters.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eConnectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated MC4 or MC4-EVO2 connectors.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eEnclosure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEMA 4X \/ IP65 rated for outdoor, roof-mounted installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQCw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eCode Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNEC Article 690 (Rapid Shutdown) and UL3741 certified.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cspan\u003eThese units act as switches, allowing the inverter to rapidly shut down DC voltage in the array to ensure safety for firefighters or during maintenance.\u003c\/span\u003e\u003c\/span\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Tesla","offers":[{"title":"Default Title","offer_id":47724835176674,"sku":"TSL-MCI-GEN2","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/5090\/1474\/files\/TSL-MCI-GEN2_1.jpg?v=1778093401","url":"https:\/\/greenvistaliving.com\/products\/tsl-mci-gen2","provider":"Green Vista Living","version":"1.0","type":"link"}