{"product_id":"enerzone-solution-3-5-wood-insert","title":"Enerzone Solution 3.5 Wood Insert","description":"\u003ch2 style=\"text-align: left;\"\u003eEnerzone Solution 3.5 Wood Insert\u003c\/h2\u003e\n\u003cp\u003eWhen the winter season sets in, it also brings \"cocooning\" rituals. Designed to replace your old ineffective masonry fireplace, the Solution 3.5 is your best choice for creating the perfect ambiance. Comfort, performance, pleasure, economy and saving are at the core of your heating experience with this wood insert designed for large spaces, in addition to being very respectful of the environment.\u003c\/p\u003e\n\u003cp\u003eThanks to its new ultra-efficient and clean secondary combustion system, this non-catalytic appliance offers a dazzling spectacle as the flames roll between the logs, through the large glass surface.\u003c\/p\u003e\n\u003cp\u003eComplete your installation with the faceplate and trims of your choice. A firescreen is also available for those who wish to fully experience the crackle of a good wood fire.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/li\u003e\n\u003cli\u003eOptimum efficiency : 77 %\u003c\/li\u003e\n\u003cli\u003eAverage particulate emissions rate : 1.32 g\/h\u003c\/li\u003e\n\u003cli\u003eSteel thickness – top : 3\/8\"\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency certified appliance : Yes, EPA 2020 approved\u003c\/li\u003e\n\u003cli\u003eRecommended heating area-ft² : 1,000 - 2,700\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlower included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"h2\"\u003e\n\u003cstrong\u003eAppliance Performance \u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eFuel type :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDry cordwood (16\" recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eRecommended heating area-ft² :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1,000 - 2,700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall firebox volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eEPA loading volume-ft³ :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eMaximum heat output-dry cordwood :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110,000 BTU\/h (32.2 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOverall heat output rate \u0026lt; :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e18,100 BTU\/h (5.3 kW) to 49,500 BTU\/h (14.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage overall efficiency (dry cordwood) :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e71 % (HHV)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e76 % (LHV)\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum overall efficiency :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e77 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eOptimum heat transfer efficiency :\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e76 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage particulate emissions rate :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.32 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"p-head-table-spec\"\u003eAverage CO :\u003cspan\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e92 g\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp id=\"note-order-1\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e1\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eValues are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.\u003c\/p\u003e\n\u003cp id=\"recommended-maximum\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e\u003cspan class=\"iconfont iconfont-asterisk\"\u003e\u003c\/span\u003e\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eRecommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.\u003c\/p\u003e\n\u003cp id=\"note-order-3\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e2\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe maximum heat output (dry cordwood) is based on a loading density varying between 15 lb\/ft³ and 20 lb\/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb\/ft³ and 12 lb\/ft³. The moisture content is between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-4\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e3\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eAs measured per CSA B415.1-10 stack loss method.\u003c\/p\u003e\n\u003cp id=\"note-order-5\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e4\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHigher Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-6\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e5\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eLower Heating Value of the fuel.\u003c\/p\u003e\n\u003cp id=\"note-order-7\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e6\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ePerformances based on a fuel load prescribed by the standard at 7 lb\/ft³ and with a moisture content between 19% and 25%.\u003c\/p\u003e\n\u003cp id=\"note-order-8\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e7\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eOptimum overall efficiency at a specific burn rate (LHV).\u003c\/p\u003e\n\u003cp id=\"note-order-9\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e8\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThe optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.\u003c\/p\u003e\n\u003cp id=\"note-order-10\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e9\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eThis appliance is officially tested and certified by an independent agency.\u003c\/p\u003e\n\u003cp id=\"note-order-11\" class=\"small\"\u003e\u003csup\u003e(\u003cstrong\u003e10\u003c\/strong\u003e)\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eCarbon monoxyde.\u003c\/p\u003e\n\u003ch3 class=\"h2\"\u003e\n\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"table-overflow\"\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-catalytic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes, EPA 2020 approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLoading over width and over depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLiner - ULC-S635, CAN\/ULC-S640, UL1777\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15'\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC-Cast or equivalent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle, glass with cast iron frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCeramic glass\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 3\/4\" X 12 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e29 1\/2\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 5\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e12 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 7\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 1\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox lined with refractory bricks for better heat distribution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel thickness – body\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/16\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteel thickness – top\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace opening – minimum (Height)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e26 1\/4\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace opening – minimum (Width)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFireplace opening – minimum (Depth)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e18 3\/8\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEPA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian Standard (emissions)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA B415.1-10\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 1482, UL 737\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCanadian standard (safety)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eULC S628\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBy an accredited laboratory (CAN\/USA)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLimited lifetime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eClearance to Combustibles\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"table-block site-margin no-margin-bottom\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cspan class=\"bold\"\u003eMinimum clearances to combustibles*\u003c\/span\u003e\u003cbr\u003e\u003cem\u003e(Data expressed in inches. 1 inch = 25.4 mm)\u003c\/em\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eCanada\u003c\/td\u003e\n\u003ctd colspan=\"1\" align=\"center\"\u003eUnited-States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – top (measured from the platform on which the appliance is installed)**\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible top mantle to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – combustible side wall to unit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e19\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance - from the top of the unit to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance – from the top of the insert to the shelf\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e27\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp class=\"small\"\u003e* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and\/or web sites).\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp class=\"small\"\u003e** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Enerzone","offers":[{"title":"Default Title","offer_id":48233750429922,"sku":"EB00062","price":3479.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/5090\/1474\/files\/enerzone-solution-3-5-wood-insert-38850561081583.jpg?v=1787080004","url":"https:\/\/greenvistaliving.com\/products\/enerzone-solution-3-5-wood-insert","provider":"Green Vista Living","version":"1.0","type":"link"}